The Trillium 120 PA made by Nanometrics.
Pool Contents
Seismometer 16 Units:Trillium 120 PA
Mechanical Parameters
Sensor 3 symmetric triaxial sensors
Signal Output
Generator Constant 1200 Vs/m
Response Ground velocity from 120 sec to 145 Hz, but +7dB @ 30 Hz
Max. Output ±20 V
Physical Parameters
Power Consumption 0.62 W @ 15 V
Weight 7.5 kg
Operating Temperatures -20 to +50 °C